Data Domain : File System (DDFS) is disabled due to a critical condition on platform
Summary: This KB describe behaviour of DDFS disabled due to platform critical condition.
Article Content
Symptoms
When Data Domain platform detects a critical condition, a safeguard will disable the file system (DDFS) as a precaution.
- Event posted: p0-12 EVT-ENVIRONMENT-00052: File system is disabled due to a critical condition.EVT-OBJ::Enclosure=1 EVT-INFO::Cause=XXXXX
Some of the typical causes of such critical conditions on platform are namely :
- Alert: EVT-ENVIRONMENT-00032: The storage processor has failed
- Alert: EVT-ENVIRONMENT-00036: The current temperature exceeds the warning threshold
- System time backwards jump
Cause
In the DD, the "messages.engineering" log (which can be viewed through "log view debug/messages.engineering" from the CLI) indicates "platmon" process disables the DDFS due to the fatal error in platform, for example :
May 11 20:55:46 dd01 cpe: DEBUG: epe_process_event: Received event: PS_ENVIRONMENT_00032 May 11 20:55:46 dd01 cpe: NOTICE: evaluate_symbol_node: taking action(s) on system_unstable(TRUE) May 11 20:55:46 dd01 cpe: NOTICE: post_event: Publishing pubsub event PS_HA_SYSTEM_STATUS May 11 20:55:46 dd01 platmon: INFO: Added indict SP May 11 20:55:46 dd01 platmon: INFO: STAT AddPersistentIndictment INFO: SP May 11 20:55:46 dd01 platmon: ERROR: Fatal error in platform monitor, DDFS shall be disabled
Resolution
Data Domain: The Data Domain File System (DDFS) may be disabled if there is a backwards jump in system time configured on the system
For other possible reasons for the platform errors and the DDFS process being disabled as a result, please read on, and contact DELL DataDomain Support as needed.
1. Firstly step should be taken to check the cause of the platform critical error and fix it. Check the mentioned "messages.engineering" log and list the system alerts (alerts show current) for any details.
2. After the platform error is fixed, clear the active EVT-ENVIRONMENT-00052 alert and also clear the "indict" as explained below :
# system show serialno # priv set se ---- Input serial number as password. # alerts show current # alerts clear alert-id <alert-id-list> # se indict list # se indict remove <id>
3. Finally, enable file system again:
# filesys enable
전산실 에어컨 및 항온 항습기가 문제가 발생하여, 온도 상승으로 인해 Data Domain이 강제 종료 되어 부팅 하였을때
해당 메시지와 함께 Filesystem 비활성화 상태 해결
1. 에어컨 및 항온 항습기를 정상정인 상태로 만들어 전산실 환경을 정상적인 상태로 변경
2. 문서를 참고하여 해당 문제 Clear
3. 재부팅 하여 해당 문제 해결
DD6400에서 해당 문제가 발생하여 해결함
(개인 knowledge 저장용)
'Backup > DataDomain' 카테고리의 다른 글
Data Domain - SE Mode (0) | 2023.07.18 |
---|---|
Data Domain: Adding External Storage Capacity (ES30/DS60) while the System is online (0) | 2021.06.07 |
Data Domain: DDOS 7.x의 최소 중단 업그레이드 (MDU) 및 DDOS 7.2 호환성 (0) | 2021.06.07 |
Data Domain: DD3300 Mapping disk alerts to the correct physical disk slot (0) | 2021.05.14 |
일반적인 DDOS(Data Domain Operating System) 업그레이드 지침 (0) | 2021.05.14 |
댓글